HP (Hewlett-Packard) A3100-8 DC EI Switch User Manual


 
By default, you can log in to the device through the console port without authentication and have user
privilege level 3 after login. For information about logging in to the device with the default configuration,
see “Configuration requirements.”
Configuration procedure
Follow these steps to configure none authentication for console login:
To do… Use the command… Remarks
Enter system view system-view
Enter AUX user interface view
user-interface aux first-number
[ last-number ]
Specify the none authentication
mode
authentication-mode none
Required
By default, you can log in to the
device through the console port
without authentication, and have
user privilege level 3 after login.
Configure common settings for
AUX user interface view
Optional
See “Configuring common settings
for console login (optional).”
After the configuration, the next time you log in to the device through the console port, you are prompted
to press Enter. A prompt such as <HP> appears after you press Enter, as shown in Figure 9.
Figure 9 Configuration page