HP (Hewlett-Packard) B6191-90028 Computer Monitor User Manual


 
Chapter 4
Using the Peripheral Status Monitor
Monitoring Request Parameters
77
EMS_NORMAL_OID "1.3.6.1.4.1.11.2.3.1.7.0.1" - Normal notification
EMS_ABNORMAL_OID "1.3.6.1.4.1.11.2.3.1.7.0.2" - Abnormal notification
EMS_RESTART_OID "1.3.6.1.4.1.11.2.3.1.7.0.4" - Restart notification
Specify the ITO message severity for both normal and abnormal events:
Critical
Major
Minor
Warning
Normal
A specified severity other than Normal is returned under the following conditions:
Certain SNMP trap monitoring requests can map directly to severity levels. For these requests, a toggle
button <Map severity from value> is displayed. If this is selected, options selected from <Severity> are
ignored.
•The When value is… condition evaluates to TRUE
•The When value changes condition evaluates to TRUE
To set the SNMP trap:
1. Specify the notification type from the <Notify> list.
2. Select the opcmsg ITO option from the <Notify via> list.
3. Select the severity from the <Severity> list, (Critical, Major, Minor, Warning, Normal).
TCP and UDP
This option sends TCP or UDP encoded events to the target host name and port indicated for that request.
Thus the message can be directed to a user-written socket program.
To set the TCP or UDP conditions:
1. Select the TCP or UDP option, as appropriate, from the <Notify via> list.
2. Specify the target host name and the port.
email
This option sends event notification to the specified email address
To set for email notification:
1. Select the Email option from the <Notify via> list.
2. Specify the full email address in the Email Address field.
syslog
This option sends event notification to the system log.
For an abnormal event, a system logging level of error will be associated with the logged message.
An abnormal event message (error) is returned under the following conditions:
•The When value is . . . condition evaluates to TRUE