HP (Hewlett-Packard) C-Series Switch User Manual


 
Merging zones-examples
22 Fabric Interoperability: Merging Fabrics Based on C-Series and B-Series Fibre Channel Switches Application Notes
Effective configuration:
cfg: mdscore1
zone: vz11 10:00:00:00:c9:24:3d:90
50:06:01:60:88:02:90:cb
zone: vz22 10:00:00:00:c9:24:3f:75
21:00:00:20:37:a7:ca:b7
21:00:00:20:37:a7:c7:e0
21:00:00:20:37:a7:c7:df
zone: vz33 10:00:00:e0:69:f0:43:9f
21:00:00:20:37:28:31:6d
21:00:00:20:37:28:24:7b
21:00:00:20:37:28:22:ea
21:00:00:20:37:28:2e:65
21:00:00:20:37:28:26:0d
This is correct. The new configuration is effective and defined.
Now let us have a look at the other switches in the fabric.
C-Series switches
MDS9509# show zoneset active
zoneset name mdscore1 vsan 1
zone name vz11 vsan 1
* fcid 0x610400 [pwwn 10:00:00:00:c9:24:3d:90]
* fcid 0x630500 [pwwn 50:06:01:60:88:02:90:cb]
zone name vz22 vsan 1
* fcid 0x630400 [pwwn 10:00:00:00:c9:24:3f:75]
* fcid 0x6514e2 [pwwn 21:00:00:20:37:a7:ca:b7]
* fcid 0x6514e4 [pwwn 21:00:00:20:37:a7:c7:e0]
* fcid 0x6514e8 [pwwn 21:00:00:20:37:a7:c7:df]
zone name vz33 vsan 1
* fcid 0x651500 [pwwn 10:00:00:e0:69:f0:43:9f]
* fcid 0x6105dc [pwwn 21:00:00:20:37:28:31:6d]
* fcid 0x6105e0 [pwwn 21:00:00:20:37:28:24:7b]
* fcid 0x6105e1 [pwwn 21:00:00:20:37:28:22:ea]
* fcid 0x6105e2 [pwwn 21:00:00:20:37:28:2e:65]
* fcid 0x6105e4 [pwwn 21:00:00:20:37:28:26:0d]
zone name $default_zone$ vsan 1
Notice the ‘show zone’ command displays the zones we created earlier on this switch.