A Emulex CNA specifications
This chapter contains the following CNA specifications:
• “Environmental specifications” (page 22)
• “Physical specifications” (page 22)
• “Emulex CNA media specifications” (page 23)
Environmental specifications
Table 3 (page 22) lists the CNA environmental specifications.
Table 3 Environmental specifications
MaximumMinimumEnvironment
55°C (131°F)0°C (32°F)Operating temperature
70°C (158°F)–40°C (–40°F)Storage temperature
85%5%Relative humidity (non-condensing)
N/A150 lf/min (minimum)Airflow
Physical specifications
Table 4 (page 22) lists the physical specifications.
Table 4 Physical specifications
RangeParameter
Minimum eight-lane PCI Express slotPICe slot requirements
Low-profile form factor, 6.60 inches by 2.71 inches, and accommodates both the
full-height and low-profile bracket
Physical dimension
14.5 Watts typicalPower requirements
Agency approvals
• Class 1 Laser Product per DHHS 21CFR (J) & EN60825-1
• UL recognized to UL60950-1 2nd Edition
• CUR recognized to CSA 22.2, No. 60950-1-07
• TUV certified by to EN60950-1
• FCC Rules, Part 15, Class A
• Industry Canada, ICES-003, Class A
• EMC Directives 2004/108/EEC (CE Mark)
EN55022, Class A
EN55024
• Australian EMC Framework (C-Tick Mark)
AS/NZS CISPR22:2006 Class A
• Japan VCCI, Class A
• Taiwan BSMI, Class A
• Korea KCC, Class A
• RoHS Compliant (Directive 2002/95/EC)
• China RoHS compliant
22 Emulex CNA specifications