System Fans
4 non-hot plug system fans ship standard with 1P models, optional upgrade to N+1 redundant.
7 non-hot plug system fans ship standard with 2P models, N+1 Redundant Standard
Operating Systems
and Virtualization
Software Support for
ProLiant Servers
Microsoft Windows Server
Microsoft Windows Server 2008 Hyper V
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Solaris 10 for x86/x64 based Systems
VMware
Citrix Essentials for XenServer (Retail)
NOTE:
For more information on HP's Certified and Supported ProLiant Servers for OS and
Virtualization Software and latest listing of software drivers available for your server, please visit
our Support Matrix at:
http://www.hp.com/go/supportos
and our driver download page
http://www.hp.com/support/DL165G7
.
Rack Airflow
Requirements
Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for
maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION:
If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must
allow 5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom to permit
adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must
be a minimum of 7 cm (2.75 inches)
CAUTION:
Always use blanking panels to fill all remaining empty front panel U-spaces in the
rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
NOTE:
For additional information, refer to the Setup and Installation Guide or the Documentation
CD provided with the server, or to the server documentation located in the Support section at the
following URL:
www.hp.com/servers/dl165
.
Rack Support
The DL Fixed Rail System supports installation in racks with square or round mounting holes
(including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 24" - 36".
Telco Rack Support
Installation into Telco 2 post, and 4 post, or threaded holes racks requires a 3rd party option kit.
For additional information, please visit:
www.hp.com/go/rackandpower
NOTE:
The 4 post Telco racks also supported.