HP (Hewlett-Packard) FB910 All in One Printer User Manual


 
0706473 Revision A 5
Preparing for Your New Printer
Table 2: Specifications
Dimensions (Assembled) Height:
Depth without tables:
Depth with tables:
Width:
63 inches (160 cm)
49 inches (124 cm)
121 inches (307 cm)
179 inches (454 cm)
Weight (Assembled) Printer without tables:
Tables only:
1675 pounds (761 kg)
150 pounds (68 kg)
Operating Conditions Temperature: 68–85° F (20–30° C)
Relative Humidity: 20–80%, non-condensing
Storage Conditions Temperature: -30–120° F (-34–49° C)
Relative Humidity: 10–80%, non-condensing
Agency Compliance Safety: CE, UL, c-UL
Emissions: FCC-A, CE
Immunity: CE
Compressed Air (Shop Air) Customer-supplied, 80-100 psi (5-7 bar)
Electrical Power
Power used: 200-240 VAC, three phase (3
φ), 50/60 Hz, 16 Amps maximum
Required electrical circuit:
North America/Japan
200-240 VAC, 20 Amps, 3
φ, with NEMA L21-20R locking wall receptacle, OR
200-240 VAC, 20 Amps, 3
φ, 60 Hz, with NEMA L15-20R locking wall receptacle and
“Phase Perfect” Digital Phase Converter Model DPC-A10
Europe
200-250 VAC, 16 Amps, 3
φ, 50 Hz, with 5-pin IEC 60309 wall receptacle
NEMA L21-20R receptacle
4-pole 5-wire grounding
20A 3-phase
Locking
OR
NEMA L15-20R receptacle
3-pole 4-wire grounding
20A 3-phase
Locking
With utility-supplied 3-phase: With 60 Hz 1-phase and
phase converter:
IEC 60309 receptacle
5-pin
16A 3-phase
200-240 VAC