HP (Hewlett-Packard) GbE2 Server User Manual


 
21
Switch ports per server blade enclosure
Eight external 10/100/1000T (C-GbE2) or 1000SX (F-GbE2) Gigabit Ethernet ports on a hot-pluggable rear-mounted
interconnect module
Four external 10/100/1000T Gigabit Ethernet ports on switch front panels
Two external DB-9 serial ports on switch front panels (one per switch)
32 internal 10/100/1000 Gigabit Ethernet ports to server blade network adapters (4 per server bay)
Two internal 10/100/1000 Gigabit Ethernet inter-switch crosslinks for switch to switch communication and failover
scenarios
10 gigabit fabric for future layer 7 switching and 10 Gigabit Ethernet uplink cpability
16 BL20p G2 Fibre Channel pass-though signals (with GbE2 Storage Connectivity Kit)
I
2
C Switch to management module communications
All external Ethernet ports may be used for data, switch and iLO management, and/or PXE remote configuration.
All internal Ethernet signals routed as Ethernet across individual CAT5e signal traces
12 RJ-45 (C-GbE2) or 8 LC fiber and 4 RJ-45 (F-GbE2) external Ethernet port connectors
16 pluggable, small form factor external slots for Fibre Channel port connectors (with GbE2 Storage Connectivity Kit)
Switch physical and environmental
AC power input (at server blade system level)
Direct facility -48 DC power input
81 Typical and 113 maximum power consumption per switch (watts)
Local front power reset/power cycle button on each switch
Remote reset/power cycle via user interface
10 to 35 operating and -30 to 60 storage temperature (Celsius)
20% to 80% operating and 5% to 95% storage relative humidity
FCC Class A, ICES-003 Class A, AS/NZS 3548 Class A, and VCCI Class A electromagnetic interference (EMI) certifications
UL/CUL and CE safety certifications
12.0 pounds per interconnect switch and interconnect module