HP (Hewlett-Packard) LXR 8000 Server User Manual


 
14
Install the HP Model 30/FC High Availability Disk Array
1. Check Power Requirements
Refer to the disk array DC power requirements in the Reference
chapter of the Hewlett-Packard Model 30/FC High
Availability Disk Array Service Manual (part number A3661-90002) to make sure the installation site meets these
requirements.
The HP Model 30/FC High Availability Disk Array uses 200VAC to 240VAC nominal; 110VAC is not supported. One
power distribution unit (PDU) in the cabinet can provide sufficient power for one, two, or three disk arrays. The disk
array and HP FC-AL hub are connected to the PDU; the PDU is connected to an UPS.
Make sure the UPS is capable of supplying an amount of power equal to the sum of the VA units required to power all
the systems and peripherals installed in the cabinet.
Consider the type of PDU that is required. PDUs have power inlets and outlets that impinge on clearances necessary to
fully open the disk array’s fan pack door. Table 1 specifies the required PDUs for various hardware configurations
installed in one cabinet.
Table 1 – PDU Requirements
PDU part
number
PDU product
number Description Typical application Racking restrictions
E5929-63001 E5929A - Universal PDU
- Ten C-13 and one C-19
outlets
- One C-20 inlet for
detachable cords
C-19 outlet is for SPUs
requiring a 20-amp
connector.
C-20 inlet facilitates a
universal set of
detachable power cords.
Typically, for external
UPS applications
Must be racked on rails at or
above 4 EIAs to clear the
C-19 outlet.
If the C-19 outlet is not
used, must be racked on
rails at or above 1 EIA to
clear the C-20 inlet.
E5931A - N. America 220 V PDU
- Ten C-13 outlets
- Attached 3 m power
cord with L6-30P plug
Attached to a 3.0 or 5.5
kva N. American UPS
None
E5932A - Europe 220 PDU
- Ten C-13 outlets
- Attached 3 m power
cord without plug
Attached to a 3.0 or 5.5
kva European UPS
None
E4456-63001 E4456B - N. America 220 V PDU
- Ten C-13 and one C-19
outlets
- Attached power cord
with L6-20P plug
C-19 outlet is for SPUs
requiring a 20-amp
connector.
Power cord typical for
N. America wall outlet
connection.
Must be racked on rails at or
above 4 EIAs to clear the
C-19 outlet.
If the C-19 outlet is not
used, must be racked on the
bottom of the rack without
rails.
E4457-63001 E4457B - Europe 220 V PDU
- Ten C-13 and one C-19
outlets
- Attached power cord
without a plug
C-19 outlet is for SPUs
requiring a 20-amp
connector.
Power cord has stripped
ends for attaching
localized plug.
Must be racked on rails at or
above 4 EIAs to clear the
C-19 outlet.
If the C-19 outlet is not
used, can be racked on the
bottom of the rack without
rails.
C2786-63006 E4456A - N. America
220 V PDU
- Ten C-13 outlets
- Attached power cord
with L6-20P plug
None
C2786-63007 E4457A - Europe 220 V PDU
- Ten C-13 outlets
- Attached power cord
without plug
Power cord has stripped
ends for attaching
localized plug.
None