14.54 Write Uncorrectable Ext (45h)
Command Block Output Registers Command Block Input Registers
Register 7 6 5 4 3 2 1 0 Register 7 6 5 4 3 2 1 0
Data Low - - - - - - - - Data Low - - - - - - - -
Data High - - - - - - - - Data High - - - - - - - -
Current - - - - - - - - Error ...See Below... Feature
Previous - - - - - - - -
Current V V V V V V V V HOB=0 - - - - - - - -Sector Count
Previous V V V V V V V V
Sector Count
HOB=1 - - - - - - - -
Current V V V V V V V V HOB=0 V V V V V V V VLBA Low
Previous V V V V V V V V
LBA Low
HOB=1 V V V V V V V V
Current V V V V V V V V HOB=0 V V V V V V V VLBA Mid
Previous V V V V V V V V
LBA Mid
HOB=1 V V V V V V V V
Current V V V V V V V V HOB=0 V V V V V V V VLBA High
Previous V V V V V V V V
LBA High
HOB=1 V V V V V V V V
Device - 1 - - - - - - Device - - - - - - - -
Command 0 1 0 0 0 1 0 1 Status ...See Below...
Error Register Status Register
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR
0 0 0 V 0 V 0 0 0 V 0 V - 0 0 V
Table 138 Write Uncorrectable Ext Command (45h)
The Write Uncorrectable Ext command is used to cause the device to report an uncorrectable
error when the target sector is subsequently read.
When the feature field contains a value of 5xh, the Write Uncorrectable Ext command causes
the device to indicate a failure when reads to any of the sectors that are contained in specified
sectors. Theses sectors are referred to as pseudo uncorrectable sectors. In this case
whenever a pseudo uncorrectable sector is accessed via a read command, the device performs
normal error recovery and then set the UNC and ERR bits to indicate she sector is bad.
When the feature field contains a value of Axh, the Write Uncorrectable Ext command causes
the device to flag the specified sector as flagged uncorrectable. Flagging a logical sector
as uncorrectable causes the device to indicate a failure when reads to specified sectors are
performed. These sectors are referred to as flagged uncorrectable sectors. In this case
whenever a flagged uncorrectable sector is accessed via a read command, the device sets the
UNC and ERR bits without normal error recovery to indicate the sector is bad.
If the Uncorrectable options are set to A5h or 55h, then sectors that have been made pseudo
uncorrectable are listed as failed in the standard error logs when read back. If the
Uncorrectable options are set to 5Ah or AAh, then the reading of pseudo uncorrectable sectors
are not logged as an error in any standardized error logs.
The pseudo uncorrectable or flagged uncorrectable status of a sector remains through a power
cycle.
If an uncorrectable error occurs, the write will be terminated at the failing sector.
Output Parameters To The Device
Feature Current
Uncorrectable options
55h : Create a pseudo uncorrectable error with logging
5Ah: Create a pseudo uncorrectable error without logging
A5h: Create a flagged error with logging
AAh: Create a flagged error without logging
Other: Reserved (command is aborted)