Hitachi HUS103014FL3800 Computer Drive User Manual


 
Drawing No. Sheet No. Revision
K6610091 40/43 2005/2/23
12.2.2 Disable Auto Start
WIDE LVD
No. Option Jumper Connector (C3) Meaning
Remove the Jumper Socket
for C3-9,10 (Default)
1
Install the Jumper Socket
for C3-9,10
2 Spindle motor starts only
by SCSI command
Spindle motor automatically
starts when the power is
applied or in sequence via ID
number x 10 seconds from the
time power is applied if
C3-13,14 is jumpered.
1
2
9
10
23
24
1
2
9
10
23
24
12.2.3 Force Single-Ended bus mode
WIDE LVD
No. Option Jumper Connector (C3) Meaning
Remove the Jumper Socket
for C3-11,12 (Default)
1
Install the Jumper Socket
for C3-11,12
2
The drive can be used as
single-ended or low voltage
differential mode.
The drive is forced to operate
only in single-ended mode.
2
1
2
11 23
12 24
12 24
1
11 23