Code 32 Pharmaceutical (PARAF)
Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital-
ian pharmacies. This symbology is also known as PARAF.
Full ASCII
If Full ASCII Code 39 decoding is enabled, certain character pairs within
the bar code symbol will be interpreted as a single character. For example:
$V will be decoded as the ASCII character SYN, and /C will be decoded as
the ASCII character #. Default = Off.
NUL %U DLE $P
SP SPACE
00@%VPP‘%Wp+P
SOH $A
DC1 $Q !/A 11AAQQa+Aq+Q
STX $B
DC2 $R “/B 22BBRRb+Br+R
ETX $C
DC3 $S #/C 33CCSSc+Cs+S
EOT $D
DC4 $T $/D 44DDTTd+Dt+T
ENQ $E
NAK $U %/E 55EEUUe+Eu+U
ACK $F
SYN $V &/F 66FFVVf+Fv+V
BEL $G
ETB $W ‘/G77GGWWg+Gw+W
BS $H
CAN $X (/H 88HHXXh+Hx+X
HT $I
EM $Y )/I 99IIYYi+Iy+Y
LF $J
SUB $Z */J :/ZJJZZj+Jz+Z
VT $K
ESC %A +/K ;%FKK[%Kk+K{%P
FF $L
FS %B ,/L <%GLL\%Ll+L|%Q
CR $M
GS %C -- =%HMM]%Mm+M}%R
SO $N
RS %D .. >%INN^%Nn+N~%S
SI $O
US %E //O?%JOO_%Oo+ODEL %T
* Off