2 - 32
Block Check Character
When this selection is set to Transmit, the NCR Block Check Character
(BCC) is expected with incoming messages and transmitted with outgoing
messages. Default = Transmit.
NCR Prefix
This selection allows you to program an NCR-specific prefix. Refer to the
ASCII Conversion Chart (Code Page 1252) on page A-3 to find the hex
equivalent for the characters you want for the NCR prefix (typically, 02 for
STX). Scan the bar code below, then set the hex number (from 0-FF) by
scanning digits from the Programming Chart, then scanning Save. Default
= 0.
NCR Suffix
This selection allows you to program an NCR-specific suffix. Refer to the
ASCII Conversion Chart (Code Page 1252) on page A-3 to find the hex
equivalent for the characters you want for the NCR suffix (typically, 03 for
ETX). Scan the bar code below, then set the hex number (from 0-FF) by
scanning digits from the Programming Chart, then scanning Save. Default
= 0.
* Transmit
Don’t Transmit
NCR Prefix