Intercharacter Delay
An intercharacter delay of up to 495 milliseconds may be placed between the
transmission of each character of scanned data. Scan the Intercharacter
Delay bar code below, then scan the number of steps in 5 millisecond incre-
ments and the Save bar code using the inside the back cover of this manual.
To remove this delay, scan the Intercharacter Delay bar code, then set the
number of steps to 0. Scan the Save bar code using the inside the back cover
of this manual.
Note: Intercharacter delays are not supported in USB serial.
User Specified Intercharacter Delay
An intercharacter delay of up to 495 milliseconds may be placed after the trans-
mission of a particular character of scanned data. Scan the Delay Length bar
code below, then scan the number of steps in 5 millisecond increments and the
Save bar code using the inside the back cover of this manual.
Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value
for a printable character to trigger the delay (see Lower ASCII Reference Table
on page A-5). The range is 00-FF.
1 2345
Intercharacter Delay
Prefix Scanned Data Suffix
Intercharacter Delay
Delay Length
Character to Trigger Delay