Honeywell NETAXS-123 Network Hardware User Manual


 
60 www.honeywell.com
Installing the NetAXS-123 Panels
Hardware Specifications
5.0 Hardware Specifications
The specifications in this section apply to both the Standard Enclosure and Compact Enclosure panels.
5.1 Relay Contacts
Maximum of six Form-C SPDT relays, 3A (at dry contact) or 0.5A (at self-whetted) @ 30VDC (PTC
limited in the self-whetted mode). The Form-C SPDT relays are configured as Normally Open or
Normally Closed outputs only. Normally Open and Normally Closed contacts cannot be used
simultaneously.
5.2 Reader Interface
Reader Power: 12VDC nominal with 500mA maximum for each reader port.
Reader LED Output: Open collector driver capable of sinking up to 8mA.
Reader Tamper: Supervised or non-supervised input.
Reader Data Input: TTL compatible inputs.
5.3 Maximum Output Loading
Use the following guidelines unless you are using Power Over Ethernet (PoE):
Maximum current per reader port for any of the three reader outputs is 500mA.
Maximum current for any of the six relay outputs on the Songchuan 892N-1CH-1F-V is 3A at
dry contact, or 0.5A at self-whetted.
Maximum battery charge current for the battery wired in series is 250mA.
External power on C-TB9 is limited to 1.5A @ 12VDC.
5.4 PoE Power Limitations
If you are using the NetAXS-123 Standard Enclosure and powering the panel with PoE (Power over
Ethernet), you must comply with these specifications for proper operation:
A NetAXS-123 panel powered by PoE is 802.3af compliant, providing a maximum of 15.4W
of input power to the panel. This input power is split between on-board power consumption and
external load consumption. A maximum current capacity of 450 mA @ 12VDC is available for
all external devices combined.
Notes:
Two readers per door can still be supported as long as the total current is within the
external load capacity stated above.
You can either find the devices’ power consumption amounts by referring to the
products’ documentation or by using a current meter.