IBM 42E Personal Computer User Manual


 
NetBAY 42 Enterprise Rack (Type 9308 Models 42P, 42X, 4SA, 4SB, 42S, 42E) 103
Installing a flat panel monitor rack mount kit
You can store a T54 or T55 Flat Panel Monitor in a keyboard tray with the flat panel
monitor rack mount kit. This kit requires an additional 2U of space above an installed
keyboard tray in your rack cabinet. See the documentation that comes with the flat
panel monitor rack mount kit for detailed installation instructions. Use the following
general procedure to install a flat panel monitor in your rack cabinet:
Figure 45. Installing a flat panel monitor rack mount kit
1. Ensure that a keyboard tray is properly installed in your rack cabinet (see
Keyboard tray on page 101) with at least 2U of clearance above the keyboard
tray.
2. Install the flat panel monitor base on the flat panel monitor. See the
documentation that comes with your flat panel monitor rack mount kit for
detailed installation instructions.
3. Install the mounting studs and bumpers on the keyboard tray.
4. Attach the monitor base to the inside of the keyboard tray using the screws that
come with the rack mount kit.
5. Fold the monitor all the way down against the bumpers; then, slide the keyboard
tray into the rack cabinet to ensure that there is proper clearance.
6. See the documentation that comes with your flat panel monitor for information
on how to connect power and how to connect the monitor to a server or console
switch.
Removing the existing flat panel monitor stand
Use the following steps to remove the existing flat panel monitor stand from your
monitor:
Keyboard tray
Rear screws
Flat panel monitor
Mounting studs
Bumpers