Symptom-to-FRU index 157
201 (Memory test error, see
"Memory Settings" on page 49.)
If the server does not have the
latest level of BIOS installed,
update the BIOS to the latest
level and run the diagnostic
program again.
1. Run memory diagnostics.
2. DIMM
3. Memory card
4. Processor/PCI Board
5. I/O Legacy Board
229 (Cache error) 1. Processor
2. Optional Processor (if installed)
3. Processor/PCI Board
289 (DIMM has been disabled by
user or system, see "Memory
Settings" on page 49.)
1. Run Configuration/Setup, if disabled by user
2. Disabled DIMM, if not disabled by user.
3. Processor/PCI Board
301 (Keyboard or keyboard
controller error)
1. Keyboard
2. I/O Legacy Board
303 (Keyboard controller error) 1. I/O Legacy Board
2. Keyboard
602 (Invalid diskette boot
record)
1. Diskette
2. Diskette Drive
3. Cable
4. I/O Legacy Board
604 (Diskette drive error) 1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. I/O Legacy Board
605 (Unlock error) 1. Diskette drive
2. Drive cable
3. I/O Legacy board
662 (Diskette drive configuration
error)
1. Run Configuration/Setup and Diagnostics
2. Diskette Drive
3. Drive Cable
4. I/O Legacy Board
762 (Coprocessor configuration
error)
1. Run Configuration/Setup utility
2. Battery
3. Processor
4. Processor/PCI board
962 (Parallel port error) 1. Disconnect external cable on parallel port.
2. Run Configuration/Setup
3. I/O Legacy Board
11XX (System board serial port 1
or 2 error)
1. Disconnect external cable on serial port.
2. Run Configuration/Setup
3. I/O Legacy Board
Error Code/Symptom FRU/Action