v A summary report of the modules, giving:
– The total possible affinity commands
– The total possible MVS post commands
v Library totals, as for the summary report, but for only those modules selected for
the detailed run.
Figure 5 is an example of a detailed report produced by the Scanner.
CICS TRANSACTION AFFINITIES UTILITY 1995/11/24 Page 1
LOAD MODULE SCANNER - DETAILED LISTING OF CICSTEST.LOAD
Module Name - ACSA1 / Load Module Length - 00000198 / Module Entry Point - 00000028
Offset Storage Content (HEX) EDF DEBUG Possible Command Affinity
-------- ---------------------------------------------- --------- ---------------------- --------
00000360 0A02E0004900004900 00000022 WRITEQ TS Trans
00000400 0A04E8004900008902 00000028 READQ TS Trans
00000482 0A06E8004900002102 00000036 DELETEQ TS Trans
Total possible Affinity commands = 3
Total possible MVS POSTs = 0
Module Name - TRANOUT / Load Module Length - 000008B8 / Module Entry Point - 00000028
Offset Storage Content (HEX) EDF DEBUG Possible Command Affinity
-------- ------------------------------------------------- --------- ----------------------- --------
00000534 4100411031341B00411010000A021B0041104000A021B00 MVS POST (SVC) System
Total possible Affinity commands = 0
Total possible MVS POSTs = 1
CICS TRANSACTION AFFINITIES UTILITY 1995/11/24 Page 2
LOAD MODULE SCANNER - DETAILED LISTING OF CICSTEST.LOAD
LOAD LIBRARY STATISTICS
==========================================================
Total modules in library = 2
Total modules scanned = 2
Total CICS modules/tables (not scanned) = 0
Total modules in error (not scanned) = 0
Total modules containing possible MVS POSTs = 1
Total modules containing possible Affinity commands = 1
Total ASSEMBLER modules = 1
Total C/370 modules = 0
Total COBOL modules = 0
Total COBOL II modules = 0
Total PL/I modules = 0
Figure 5. Example of a detailed report produced by the Scanner
Chapter 4. Running the Scanner 29