Intel 100BASE-T4 Switch User Manual


 
1
Quick Start
1 Install the hub(s).
Maximum stack: Six hubs
Rack requirements: Standard 19-in (48.26 cm), 1.5 EIA rack-mount
space for each hub
Shelf requirements: Support for 10 lbs (4.5 kg) per hub
12.3 lbs (5.6 kg) with uplink module and NMM
2 Connect the stack.
Use the cascade cables to connect multiple hubs.
You need to purchase cascade cables separately
from your network services supplier (see
Appendix B for more information).
Do not use UTP cabling to connect hubs.
3 Connect the devices.
Connect 100BASE-T4 devices to the hub using four-pair
Category 3, 4, or 5 unshielded twisted pair (UTP) cabling.
Maximum cable distance between a port and an attached
device is 100 meters.
4 Plug power cords into each hub, then check LEDs.
Make sure the Pwr LED is lit for all hubs.
Make sure the numbered port LEDs are lit for connected devices.
Pwr LED
Port LEDs