Intel 8086-2 Computer Hardware User Manual


 
8086
EXTERNAL SYNCHRONIZATION VIA TEST
As an alternative to the interrupts and general IO
capabilities the 8086 provides a single software-
testable input known as the TEST
signal At any time
the program may execute a WAIT instruction If at
that time the TEST
signal is inactive (HIGH) pro-
gram execution becomes suspended while the proc-
essor waits for TEST
to become active It must
remain active for at least 5 CLK cycles The WAIT
instruction is re-executed repeatedly until that time
This activity does not consume bus cycles The
processor remains in an idle state while waiting All
8086 drivers go to 3-state OFF if bus ‘‘Hold’’ is en-
tered If interrupts are enabled they may occur while
the processor is waiting When this occurs the proc-
essor fetches the WAIT instruction one extra time
processes the interrupt and then re-fetches and re-
executes the WAIT instruction upon returning from
the interrupt
Basic System Timing
Typical system configurations for the processor op-
erating in minimum mode and in maximum mode are
shown in Figures 4a and 4b respectively In mini-
mum mode the MNMX
pin is strapped to V
CC
and
the processor emits bus control signals in a manner
similar to the 8085 In maximum mode the MNMX
pin is strapped to V
SS
and the processor emits cod-
ed status information which the 8288 bus controller
uses to generate MULTIBUS compatible bus control
signals Figure 5 illustrates the signal timing relation-
ships
231455–10
Figure 7 8086 Register Model
SYSTEM TIMINGMINIMUM SYSTEM
The read cycle begins in T
1
with the assertion of the
Address Latch Enable (ALE) signal The trailing (low-
going) edge of this signal is used to latch the ad-
dress information which is valid on the local bus at
this time into the address latch The BHE
and A
0
signals address the low high or both bytes From T
1
to T
4
the MIO signal indicates a memory or IO
operation At T
2
the address is removed from the
local bus and the bus goes to a high impedance
state The read control signal is also asserted at T
2
The read (RD
) signal causes the addressed device
to enable its data bus drivers to the local bus Some
time later valid data will be available on the bus and
the addressed device will drive the READY line
HIGH When the processor returns the read signal to
a HIGH level the addressed device will again 3-
state its bus drivers If a transceiver is required to
buffer the 8086 local bus signals DTR
and DEN
are provided by the 8086
A write cycle also begins with the assertion of ALE
and the emission of the address The MIO
signal is
again asserted to indicate a memory or IO write
operation In the T
2
immediately following the ad-
dress emission the processor emits the data to be
written into the addressed location This data re-
mains valid until the middle of T
4
 During T
2
T
3
 and
T
W
the processor asserts the write control signal
The write (WR
) signal becomes active at the begin-
ning of T
2
as opposed to the read which is delayed
somewhat into T
2
to provide time for the bus to float
The BHE
and A
0
signals are used to select the prop-
er byte(s) of the memoryIO word to be read or writ-
ten according to the following table
BHE A0 Characteristics
0 0 Whole word
0 1 Upper byte fromto
odd address
1 0 Lower byte fromto
even address
1 1 None
IO ports are addressed in the same manner as
memory location Even addressed bytes are trans-
ferred on the D
7
–D
0
bus lines and odd addressed
bytes on D
15
–D
8
The basic difference between the interrupt acknowl-
edge cycle and a read cycle is that the interrupt ac-
knowledge signal (INTA) is asserted in place of the
read (RD
) signal and the address bus is floated
(See Figure 6) In the second of two successive
INTA cycles a byte of information is read from bus
12