Supported IPMI Commands and BMC/PM Addresses
4.2.3 SEL Commands
All commands in this category defined as mandatory by the IPMI specification are implemented. In
addition, the following optional commands are available.
Note: SEL commands can only be used in BMC mode.
4.2.4 SDR Commands
All commands in this category defined as mandatory by the IPMI specification are implemented. In
addition, the following optional commands are available.
All commands can be used in every operation mode.
4.2.5 FRU Inventory Device Commands
All commands in this category defined as mandatory by the IPMI Specification are implemented.
The commands can be used in every operation mode.
The FRU information returned by the IPMI command “Read FRU Inventory Data” is compatible
with the Platform Management FRU information Storage Definition v1.0.
The size of the complete FRU record consisting of:
• Internal Use Area
• Board Info Area
• Product Info Area
• Multi Record Area
is limited to 1024 bytes.
Table 5. Optional SEL Device Commands
Command NetFn CMD
Get SEL Allocation Info Storage 41
16
Reserve SEL Storage 42
16
Add SEL Entry Storage 44
16
Partial Add SEL Entry Storage 45
16
Delete SEL Entry Storage 46
16
Table 6. Optional SDR Device Commands
Command NetFn CMD
Get SDR Allocation Info Storage 20
16
Add SDR Storage 24
16
Partial Add SDR Storage 25
16
Delete SDR Storage 26
16
Get SDR Repository Time Storage 28
16
Set SDR Repository Time Storage 29
16