Intel SDS2 Computer Hardware User Manual


 
Intel® Server Board SDS2 BIOS
Revision 1.2
Order Number: A85874-002
37
The BIOS logs the following SEL entries.
Table 22. BIOS Generated SEL Errors
Sensor Type
Sensor
Number
Sensor
Type
Code
Sensor-
Specific
Offset
Event
02h FRB1/BIST Failure Processor 5Fh
60h
07h
03h FRB2/Hang in POST Failure
Memory 08h 0Ch 01h Uncorrectable ECC
POST Memory
Resize
A0h 0Eh POST Memory Resize
POST Error 06h 0Fh POST Error
00h Correctable Memory Error Logging Disabled Event Logging
Disabled
09h 10h
01h Event ‘Type’ Logging Disabled
00h System Reconfigured System Event 7Ah 12h
01h OEM System Boot Event (Hard Reset)
04h PCI SERR Critical Interrupt 07h 13h
05h PCI PERR
00h Initiated by power up
03h User requested PXE boot
System Boot
Initiated
A1h 1Dh
04h Automatic boot to diagnostic
00h No bootable media
02h PXE Server not found
Boot Error A2h 1Eh
03h Invalid boot sector
00h
I2C Bus Device Address Not Acknowledged
01h
I2C Bus Device Error Detected
Sensor Failure 7Ch F6h
02h
I2C Bus Timeout
00h CNB2.0HE-SL function 0 errors Chipset Specific
Critical Interrupt
F4h F4h
02h CIOB20 #0 errors
The Event Request Message Event Data Field Contents table below describes the various fields
in the event request message sent by the BIOS.