Intel SDS2 Computer Hardware User Manual


 
Intel® Server Board SDS2 BIOS
Revision 1.2
Order Number: A85874-002
43
Sensor
Name
Sensor
#
Sensor Type
Event/
Reading
Type
Event
Offset
Triggers
Power
Supply 2
5Bh
Power Supply -
08h
Sensor
Specific - 6Fh
Presence,
Failure,
Predictive Fail,
A/C Lost
Power
Supply 3
5Ch
Power Supply -
08h
Sensor
Specific - 6Fh
Presence,
Failure,
Predictive Fail,
A/C Lost
Missing CPU
Module
5Eh
Module/Board
15h
Digital
Discrete - 03h
State Asserted
Proc 1 Status
5Fh
Processor -
07h
Sensor
Specific - 6Fh
Presence,
Thermal Trip,
IERR,
FRB1,
FRB2,
FRB3,
Disabled
Proc 2 Status
60h
Processor -
07h
Sensor
Specific - 6Fh
Presence,
Thermal Trip,
IERR,
FRB1,
FRB2,
FRB3,
Disabled
DIMM 1 68h
Slot Connector
- 21h
Sensor
Specific - 6Fh
Fault Status
Asserted,
Device Installed,
Disabled
DIMM 2 69h
Slot Connector
- 21h
Sensor
Specific - 6Fh
Fault Status
Asserted,
Device Installed,
Disabled
DIMM 3 6Ah
Slot Connector
- 21h
Sensor
Specific - 6Fh
Fault Status
Asserted,
Device Installed,
Disabled
DIMM 4 6Bh
Slot Connector
- 21h
Sensor
Specific - 6Fh
Fault Status
Asserted,
Device Installed,
Disabled
DIMM 5 6Ch
Slot Connector
- 21h
Sensor
Specific - 6Fh
Fault Status
Asserted,
Device Installed,
Disabled