Powering Off
14
Powering Off and Restarting
If it becomes necessary to power off one of the MiniView™ units, you must do the
following before restarting it.
1. Shut down all the computers that are attached to it, as well as all the stations and all
the computers that are daisy chained down from it (all the child stations and the
computers attached to them).
NOTE: (1) If the unit is operating under Bus Power (without the optional Power Adapter),
you must unplug the power cords of any PCs that are connected to it that
have the Keyboard ‘Power On’ function, otherwise the switch will still receive
power from the PC.
(2) If the unit is operating under external power, unplug the power adapter cable.
(3) It is not necessary to shut down and restart any of the stations or computers
above the station you powered off.
3. After the MiniViews are up, Power On the PCs, starting with the ones attached to
the last station in the chain and working back to the station you originally shut down.
2. Wait 10 seconds, then power on the MiniView™ GCS138 stations starting with the
last station in the chain and working back to the station you originally shut down.