Page 9
Installation
TM-1400 Series Progressive Scan Shutter Cameras
2.2.3 Shutter Speed Control Dial (TM-1400 only)
Shutter speed can be selected by switching the shutter dial to the
appropriate setting (0 through 9). The factory default settings correspond
to the shutter speeds as shown in below.
2.2.4 RS-232 Communication Cable (TM-1400 only)
FIGURE 5. Serial Communication Cable RS-232B-12
The RS-232 controller set CS-232E includes cable RS-232B-12 interface cable, software disk, and a
quick-start card. The TM-1400 camera’s built-in look-up table (LUT) can be controlled by an external
RS-232 interface. The camera settings can be programmed or changed using the communication cable
and software. Commands from the RS-232 interface will override the rear panel switch settings of the
camera. Please refer to the AccuPiXEL Series Camera-Control Software manual for details on the
graphical user interface.
TABLE 5. Shutter Speed Control Dial
Shutter Exposure Time (Seconds)
Normal Async
0 no shutter (1/30) no shutter (1/30)
1 1/60 1/16,000
2 1/125 1/8,000
3 1/250 1/4,000
4 1/500 1/2,000
5 1/1,000 1/1,000
6 1/2,000 1/500
7 1/4,000 1/250
8 1/8,000 1/125
9 1/16,000 Ext. pulse width control
0
1
2
3
4
6
7
8
9
5
Receptacle
40±3mm
75mm±5mm
Jack
1925±10mm
2000±20mm
190±5mm
6
1
59