Juniper Networks ERX-1410 Network Router User Manual


 
CHAPTER 4
Cabling the ERX System
4-2
Cabling Your ERX System
Cabling the system takes only a few minutes. You need these items:
A 1/8" flathead screwdriver – to connect the alarm leads
A 3/8" wrench or 3/8" nut-driver – to loosen and tighten hex nuts on
Power A and Power B leads
A No. 2 Phillips screwdriver – to remove the power input module
cover
Two ground wires – we recommend a minimum of 10-AWG ground
wire with a ring-style terminal.
A #10 kep nut to connect the ground (earth) wire to the ground
terminal.
We recommend that you use shielded cables where appropriate and
perform the cabling tasks in this order:
1 Familiarize yourself with the module ports. See Figure 4-1.
2 Ensure that you have the cables and wires needed to complete each
cabling procedure.
3 Read and understand all safety warnings.
4 Connect the power cables from the power source to the power input
module.
5 Connect cables to the SRP I/O module.
6 Connect cables to the line I/O modules.