JVC DT-V17G1 Computer Monitor User Manual


 
21
ENGLISH
<Functions controlled by the MAKE/TRIGGER system>
Display Functions to be controlled Opening Short-circuiting
TALLY SEL Selects the color of the tally lamp. Green Red
SDI 1 Changes the input to “SDI 1.” Invalid Valid
SDI 2 Changes the input to “SDI 2.” Invalid Valid
DVI Changes the input to “DVI.” Invalid Valid
COMPONENT Changes the input to “COMPO.” Invalid Valid
VIDEO Changes the input to “VIDEO.” Invalid Valid
3G-B.DS Selects the “3G SDI LEVEL B” data stream. DS 1 DS 2
DUAL LINK Turns on or off “SDI DUAL LINK.” Off On
A.MARKER The area marker indication Off On
S.MARKER The safety marker indication Off On
FRAME Indication of the area of
the specified aspect ratio
Off On
C.MARKER The center marker indication Off On
MARK.SEL Selects the items of “MARKER”*
3
Non-“R-” items “R-” items
ASPECT Changes the aspect ratio. 4:3 16:9
1:1 Displays in 1:1 mode. Off On
STATUS Status display*
4
“On the Status Display” on page 7
L.METER Audio level meter display *
5
TIME CODE Time code display Off On
SOURCE ID
“SOURCE ID” in “INFORMATION” on page 18
*
6
WAVE FORM Wave form monitor display *
7
VECTOR
Vector scope display *
7
COLOR OFF Color off Color Monochrome
SCR CHECK Screens check *
8
I/P MODE Change a mode according to a input picture. *
9
MUTING Muting on/off Off On
DIMMER Change the intensity of the button lamps. NORMAL DARK
– – – No function
*
3
Selects which functions in “MARKER” are activated, non-“R-” items or “R-” items. ( “MARKER” on page 13)
*
4
Displays the information shown when INPUT SELECT button of the current input is pressed ( “On the Status
Display” on page 7). While controlling with the MAKE system, the information is displayed only at the moment of
short-circuiting.
*
5
While controlling with the MAKE system, the level meter is switched between displayed (short-circuiting) and
hidden (opening). When “LEVEL METER ch” is set to “OFF,” the level meter is not displayed (“NO EFFECT”
appears).
While controlling with the TRIGGER system, the pattern of the audio channel display is switched.
*
6
While controlling with the MAKE system, the available set-up options will be the setting value currently selected
in “SOURCE ID” (“ON” or “AUTO” [short-circuiting]) and “OFF” (opening). While controlling with the TRIGGER
system, uses the same set-up option as those in the SET-UP MENU. ( “SOURCE ID” in “INFORMATION” on
page 18)
*
7
While controlling with the MAKE system, the wave form monitor and vector scope is switched between
displayed (short-circuting) and hidden (opening) regardless of the “AUTO OFF” setting in the MAIN MANU.
While controlling with the TRIGGER system, the screen is switched in the same way as when pressing the
SCOPE button ( e on page 6). If the wave form monitor and vector scope are input at the same time, the
wave form monitor is displayed.
*
8
While controlling with the MAKE system, the screen is switched between normal screen (opening) and blue
screen (short-circuiting). While controlling with the TRIGGER system, the screen changes in the same way as
when pressing SCREENS CHECK button ( q on page 6).
*
9
Must be controlled with the TRIGGER system. The mode changes in the order of “NORMAL” \ “CINEMA” \
“FIELD.” (This function cannot be controlled with the MAKE system.)
• You cannot assign the same function to different pin terminals.
• The TRIGGER system switches each function by short-circuiting the pin terminal for about 1 second and
opening it.
DT-V17G1_EN.indd 21DT-V17G1_EN.indd 21 09.12.3 7:55:21 PM09.12.3 7:55:21 PM