18
Menu Configuration (cont.)
Sync Function
Settings for the synchronization with signals.
Item To do Setting value
No Sync Action Select the screen status when no signal is coming in. Off, Standby, Power Save
(power save mode),
Gray Back (gray screen)
Delay Time Select the period until the screen status changes as selected in “No Sync Action” after signals
stop coming in.
30s, 5min, 15min
Low Latency Activates/deactivates the function to shorten the time taken to display the picture (low
latency function).
Off, On
• If the picture is not displayed steadily while “On” is selected, select “Off.”
• While “On” is selected, the displayed picture may become unstable when an operation
using buttons on the front panel or the menu is performed, or when the signal format
changes.
● When setting “No Sync Action” to “Gray Back,” the screen color changes to gray and the power consumption of the backlight is saved by half.
Selecting “Power Save” (power save mode) saves more power consumption by turning off the backlight.
No Operation Action Setting values: Off, On
Setting of the function for turning the unit off (standby) automatically when no operations are made for more than 4 hours.
Off: Does not turn off automatically
On: Turns off automatically
● When the function is turned On, a warning message will be displayed about 3 minutes before turning off automatically.
When you turn on the unit with the function turned On, a message notifying that the setting is turned on will be displayed for about 30
seconds.
Set-Up Menu
Function Setting
Settings for the sub menu display, color of the tally lamp, and the intensity of the button lamps.
Item To do Setting value
sub menu Position Select the contents and displaying position of “sub menu.”
The setting values and features are as follows.
Lower1, Upper1, Lower2,
Upper2
Lower1
: Displays the current setting and adjustment bar at the lower part of the screen.
Upper1
: Displays the current setting and adjustment bar at the upper part of the screen.
Lower2
: Displays the current setting at the lower part of the screen.
Upper2
: Displays the current setting at the upper part of the screen.
• The adjustment bar is not displayed for some items.
Tally Setting
Set the color and mode of the tally lamp using external control.
Tally Type
Normal
Half
:
:
Light up the entire tally.
Light up the left and right halves of the tally individually.
Normal, Half
Tally Color
Set the tally color when “Tally Type” is set to “Normal”. Green, Red
Dimmer Select the intensity of the button lamps. Normal, Dark
Component Phase Deactivates the function of PHASE adjustment (Picture adjustment knob and “Picture Sub
Adjust” in Set-Up Menu) except when an NTSC signal comes in (☞ on page 19).
Enable, Disable
Remote Active On
Standby
Set the conditions for the power switch by external control (serial). Off, On
Off
On
:
:
Cannot power on by external control after powered OFF.
Can power on by external control after powered OFF.
LCD Saver
Configure the setting for reducing damage to the LCD panel for long-time use. (☞ on page 22)
Setting 1st Start Set the standby time. (unit: hours) 00h-24h
Work
Time
Set the time for performing the function. (unit: hours)
01h-06h
Contrast Set the contrast reduction. Normal, Save
Backlight Reduce the backlight brightness. Normal, Save
OSD
Contrast
Set the contrast reduction of the OSD display.
Normal, Save
Side Mask Select whether to use the side panel.
* The Side Mask function works no matter whether the LCD Saver is active or stopped.
Off, On
reset Restore the default settings for all the items in “LCD Saver”.
Execute Execute the LCD Saver function.
Cancel Stop the LCD Saver function. (“Cancel” will be grayed out during the function stop.)
Status Display the LCD Saver status. Off, Ready
Start After Stop the LCD Saver function. (unit: hours and minutes) **h **min
DT-V9L5_EN_1.indb 18DT-V9L5_EN_1.indb 18 10/10/2012 5:18:52 PM10/10/2012 5:18:52 PM