Kingston Technology KNS2450/R Switch User Manual


 
Kingston Technology Company KNS3250/R User’s Guide - Rev. A00
12 Kingston Switch Conguration Utility
Aging Time
The address-aging timer is built in to the table aging process. The minimum time is
1 second and the maximum is 510 seconds. 255 is the default value, if the number
exceeds 255 it must be an even number.
Broadcast Storm Control Threshold
The Broadcast storm control function limits the number of consecutive broadast
packets for each port that has Broadcast Storm Control enabled. The broadcast
packets are stored in the buffer and sent to the other ports one by one. In the buffer,
when the number of stored broadcast packets exceeds the specied threshold, the
device will discard the consecutive incoming broadcast packets until the number
of stored broadcast packets is below the threshold. The assignable values are 16,
32, 48 and 64 with 64 being the default.
Description
This is basically a comment section for notes by the user. Up to 2048 characters
can be written. This description can only be saved and read from the disk le, the
information is not stored on the device itself.