Lantronix EDS-MD8 Switch User Manual


 
5: Commands and Levels
EDS-MD Command Reference 79
disconnect (tunnel-disconnect:7) level commands
clrscrn
Clears the screen.
exit
Returns to the tunnel level.
flush serial disable
Does not flush serial data upon closing a tunneling connection.
flush serial enable
Flushes serial data buffer when a tunneling connection is
closed.
flush stop character disable
Forwards the stop character from the Line to the network.
flush stop character enable
Prevents the stop character from the Line from being for-
warded to the network.
modem control disable
Does not watch the modem control pin to disconnect.
modem control enable
Watches the modem control pin and disconnects if it is not
asserted.
no stop character
Removes the stop character.
no timeout
Disables disconnect after timeout feature for tunneling ses-
sions.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current CLI
session.
stop character <control>
Sets the stop character.
The character may be input as text, control, decimal, or hex.
A control character has the form <control>C.
A decimal value character has the form \99.
A hex value character has the form 0xFF.
timeout <milliseconds>
Disconnects when no data has been received on the line (serial
port) for the
specified length of time.
<milliseconds> = timeout in milliseconds.
write
Stores the current configuration in permanent memory.
disconnect (tunnel-disconnect:6) level commands
clrscrn
Clears the screen.
exit
Returns to the tunnel level.
flush serial disable
Does not flush serial data upon closing a tunneling connection.
flush serial enable
Flushes serial data buffer when a tunneling connection is
closed.
flush stop character disable
Forwards the stop character from the Line to the network.
flush stop character enable
Prevents the stop character from the Line from being for-
warded to the network.
modem control disable
Does not watch the modem control pin to disconnect.
modem control enable
Watches the modem control pin and disconnects if it is not
asserted.
no stop character
Removes the stop character.
no timeout
Disables disconnect after timeout feature for tunneling ses-
sions.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current CLI
session.
stop character <control>
Sets the stop character.
The character may be input as text, control, decimal, or hex.
A control character has the form <control>C.
A decimal value character has the form \99.