Lenovo 3719 Server User Manual


 
Table 4. DSA messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.
Message
number Component Test State Description Action
201-807-xxx Memory Memory Test Aborted Test aborted:
the memory
controller buffer
free request
failed.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
“Updating the firmware” on page 267.
4. Run the test again.
5. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support.
201-808-xxx Memory Memory Test Aborted Test aborted:
memory
controller
display/alter
buffer execute
error.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
“Updating the firmware” on page 267.
4. Run the test again.
5. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support.
201-809-xxx Memory Memory Test Aborted Test aborted
program error:
operation
running fast
scrub.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the DSA code is at the latest
level.
4. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
“Updating the firmware” on page 267.
5. Run the test again.
6. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support.
201-810-xxx Memory Memory Test Aborted Test stopped:
unknown error
code xxx
received in
COMMONEXIT
procedure.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the DSA code is at the latest
level.
4. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
“Updating the firmware” on page 267.
5. Run the test again.
6. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support.
112 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual