Lenovo 3822 Server User Manual


 
1 System power-on LED
2 Hard disk drive activity LED
3 System-locator LED
4 System-information LED
5 System-error LED
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to
determine which components are customer replaceable units (CRUs) and which components are field
replaceable units (FRUs).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Lit EasyLED diagnostics LEDs with the
system-error or information LED also lit Description
System power-on (green) The states of the power-on LED are as follows:
v Off: ac power is not present, or the power supply or the LED itself
has failed.
v Flashing rapidly (4 times per second): The server is turned off
and is not ready to be turned on. The power-control button is
disabled. Approximately 3 minutes after the server is connected to
ac power, the power-control button becomes active.
v Flashing slowly (once per second): The server is turned off and is
ready to be turned on. You can press the power-control button to
turn on the server.
v Lit: The server is turned on.
v Fading on and off: The server is in a reduced-power state. To
wake the server, press the power-control button or use the IMM
Web interface.
Hard-disk drive activity (green) When this LED is flashing rapidly, it indicates that there is activity on a
hard disk drive.
System locator (blue) Use this LED to visually locate the server among other servers.
128 ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual