Lenovo 4011 Server User Manual


 
Table 17. Submenus under the Mass Storage Controller Conguration
Item Option Description
SATA Conguration Disabled / [Enabled] Enable or disable the integrated SATA
controller.
Congure SATA as [IDE] / RAID
To select the hard disk drive mode.
If this option is set to IDE, all the
SATA connectors will be congured
as stand-alone SATA connectors.
Notes:
1. The settings in [ ] are the default settings in the Setup Utility program.
2. The SATA Conguration item might not apply because your server came with an integrated SAS controller.
Table 18. Submenus under the SuperIO Conguration
Item Option Description
Serial Port1 Address Disabled / [3F8/IRQ4] / 3E8/IRQ4 /
2E8/IRQ3
Select the I/O base address and
interrupt for serial port 1.
Serial Port2 Address Disabled / [2F8/IRQ3] / 3E8/IRQ4 /
2E8/IRQ3
Select the I/O base address and
interrupt for serial port 2.
Note: The settings in [ ] are the default settings in the Setup Utility program.
Table 19. Submenus under the USB Conguration
Item Option Description
Legacy USB Support Disabled / [Enabled] / Auto
Enable or disable the support on
legacy USB devices.
USB 2.0 Controller Mode FullSpeed / [HiSpeed] Select the USB speed.
Hotplug USB FDD Support Disabled / Enabled / [Auto]
Enable or disable the support on the
hot-swap USB diskette drive.
Note: The settings in [ ] are the default settings in the Setup Utility program.
For external USB devices, the USB Mass Storage Device Conguration submenu is as below:
Emulation Type
[Auto] / Floppy / Forced FDD / Hard
Disk / CDROM
Select the type of the USB device.
Table 20. Submenus under the Hardware Health Conguration
Item Option Description
Items and options with BMC conguration:
Auto Fan Control Disabled / [Enabled]
If this option is set to Disabled, the
fan runs at the full speed; if this option
is set to Enabled, the fan speed is
controlled by the system temperature.
PWM Minimal Duty Cycle [60% Duty Cycle] / 45% Duty Cycle
/ 30% Duty Cycle
Select the PWM Minimal Duty Cycle
for the fan: 60%-100%, 45%-100%,
or 30%-100%.
Sensor Data Register Monitoring Read Only
The sensor data in this option is for
read only. The detected data includes
the temperature, voltage and fan
speed.
Items and options without BMC conguration:
Chapter 6. Conguring the server 71