Lenovo 5354 Computer Hardware User Manual


 
Diagnostic error code FRU/Action
025-196-XXX IDE interface test halt, error threshold
exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
025-197-XXX IDE interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility” on page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
025-198-XXX IDE interface test aborted 1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using the
Setup Utility” on page 41
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 99
3. Go to “Undetermined problems” on page 64
025-199-XXX IDE interface test failed, cause unknown
1. Go to “Undetermined problems” on page 64
2. Flash the system and re-test. See “Updating
(ashing) BIOS from a disc” on page 99
3. Replace component under function test
030-000-XXX SCSI interface Test Passed
No action
030-00X-XXX 030-01X-XXX SCSI interface failure 1. SCSI signal cable
2. Check AC/DC power adapter
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-027-XXX SCSI interface conguration/setup error 1. SCSI signal cable
2. Flash the system. See “Updating (ashing) BIOS
from a disc” on page 99
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-03X-XXX 030-04X-XXX SCSI interface error 1. SCSI signal cable
2. Check AC/DC power adapter
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-195-XXX SCSI interface test aborted by user
Information only Re-start the test, if necessary
030-196-XXX SCSI interface test halt, error threshold
exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
54 Hardware Maintenance Manual