Lenovo 6445 Server User Manual


 
Original bootcfg program output
Boot Loader Settings
----------------------------
timeout: 30
default: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
Boot Entries
----------------
Boot entry ID: 1
OS Friendly Name: Windows Server 2003, Standard
Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
OS Load Options: /fastdetect
Modified bootcfg program output
Boot Loader Settings
----------------------------
timeout: 30
default: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
redirect: COM1
redirectbaudrate: 19200
Boot Entries
----------------
Boot entry ID: 1
OS Friendly Name: Windows Server 2003, Standard
Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
OS Load Options: /fastdetect /redirect
You must restart the Windows 2003 operating system after you complete this
procedure for the changes to take effect and to enable SOL.
Installing the OSA SMBridge management utility program
Important: To obtain maximum benefit from the OSA SMBridge management utility
program, install and load the program before problems occur.
To install the OSA SMBridge management utility program on a server running a
Windows operating system, complete the following steps:
1. Go to http://www.lenovo.com/support/ and download the utility program and
create the OSA BMC Management Utility CD.
2. Insert the OSA BMC Management Utility CD into the drive. The InstallShield
wizard starts, and a window similar to that shown in the following illustration
opens.
56 ThinkServer RD120 Types 6444, 6445, 6446, and 6447: Installation Guide