Lenovo 6533 Computer Hardware User Manual


 
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which
components are customer replaceable units (CRU) and which components are eld replaceable units (FRU).
If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Fault in slot System board
on system %1.(%1 =
CIM_ComputerSystem.ElementName)
Error
1. Check the extender-card
LEDs.
2. Reseat the affected adapters
and extender card.
3. Update the server and adapter
rmware (UEFI and IMM).
Important: Some cluster
solutions require specic code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
4. Remove both adapters.
5. Replace the PCIe adapter.
6. Replace the extender card.
7. (Trained service technician
only) Replace the system
board.
Redundancy Bckup Mem Status has
been reduced.
Error Redundancy has been lost
and is insufcient to continue
operation.
1. Check the system-event
log for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2. Re-enable mirroring in the
Setup utility.
IMM Network Initialization Complete.
Info
An IMM network has
completed initialization.
No action; information only.
Certicate Authority %1 has detected
a %2 Certicate Error.(%1 =
IBM_CerticateAuthority.CADistinguishedName;
%2 =
CIM_PublicKeyCerticate.ElementName)
Error A problem has occurred with
the SSL Server, SSL Client,
or SSL Trusted CA certicate
that has been imported
into the IMM. The imported
certicate must contain a
public key that corresponds
to the key pair that was
previously generated by
the Generate a New Key
and Certicate Signing
Request link.
1. Make sure that the certicate
that you are importing is
correct.
2. Try importing the certicate
again.
Ethernet Data Rate modied from
%1 to %2 by user %3.(%1 =
CIM_EthernetPort.Speed; %2 =
CIM_EthernetPort.Speed; %3 = user
ID)
Info A user has modied the
Ethernet port data rate.
No action; information only.
40 Hardware Maintenance Manual