LevelOne FPS-2111TXU Printer User Manual


 
Introduction
LED Indicators
All LevelOne Printer Servers are fitted with 2 LED indicators. The red LED is the
Status/Error indicator. The green LED is the Power/Link indicator. The LED indicator
modes are described in the following table.
Green LED Red/Orange LED Status Description
Off Off No power.
On On Hardware error.
Flashing Flashing Firmware upgrade in progress.
On Flashing (USB only) No printer connected to the USB port.
On Off Normal operation - idle.
Flashing Off Normal operation - transmitting or
receiving packets from the network.
DIP Switches - FPS-2101TXU & FPS-2003TXU
The DIP switches are used to set the LAN connection. Operation is as follows.
SW1 SW2 SW3 Description
UP UP UP Auto select LAN connection (Default)
UP UP Down Use BNC connector
Down Down Down 10BaseT - Half Duplex
Down Down UP 10BaseT - Full Duplex
Down UP Down 100BaseT - Half Duplex
Down UP UP 100BaseT - Full Duplex
The other possibilities are reserved, and should not be used.
DIP Switches - FPS-2111TXU & FPS-2013TXU
The DIP switches are used to set the LAN connection. Operation is as follows.
SW1 SW2 SW3 Description
UP - - Auto select LAN connection (Default)
Switches 2 and 3 have no effect.
Down Down Down 10BaseT - Half Duplex
Down Down UP 10BaseT - Full Duplex
Down UP Down 100BaseT - Half Duplex
Down UP UP 100BaseT - Full Duplex
The other possibilities are reserved, and should not be used.
- 11 -