Troubleshooting
3. Reconfigure as for a new device.
Problem No. 6 Printing by FTP, I receive an error message:
Invalid print queue
Print queue not ready
Solution No. 6
Check that the printer is ready
Check that Logical printer(s) are defined on the LevelOne
Printer Server. With FTP, you can print ONLY to a logical
printer.
Reset the LevelOne Printer Server
Problem No. 7 I can’t print using LPD.
Solution No. 7 Try printing with FTP. If this works, the problem is the LPD
daemon on your UNIX host. Reconfigure the remote printer and the
LPD daemon. Check the following points.
The remote host name is the name of the LevelOne Printer
Server.
The remote printer name is the logical printer name on the
LevelOne Printer Server (e.g. L1).
If your UNIX asks for the LPD type, be sure to identify the
service type as BSD.
Problem No. 8 I can’t print using PSfilter,
Solution No. 8 Run PSfilter directly with the command:
PSfilter -D P_name -v <file_name&
Where:
P_name is the LevelOne Printer Server’s name
file_name is the file you wish to print.
If this fails, check for an error log file (e.g. PSErrLog XXXXX) in
the /tmp directory. If there is not an error log file, recompile
PSfilter.
Also, check the Troubleshooting section of the Psfilter .TXT file
for your system.
Problem No. 9 The “String Before Job” and/or “String After Job” settings in
the Logical Printers don’t work properly
Solution No. 9
Check the length of the control strings. No string can exceed
15 characters.
Check that the control strings are in HEX.