LG Electronics 55WS10 Computer Monitor User Manual


 
76
ENG
ENGLISH
CONTROLLING THE MULTIPLE PRODUCT
23. Key (Command: m c)
To send IR remote key code.
Transmission
[m][c][ ][Set ID][ ][Data][Cr]
Data
Key code : Refer to ‘IR CODES’.
Acknowledgement
[c][ ][Set ID][ ][OK][Data][x]
26. 4 Hours Off (Command: m n)
To set the 4 Hours Off function.
Transmission
[m][n][ ][Set ID][ ][Data][Cr]
Data
00: 4 Hours Off Off
01: 4 Hours Off On
Acknowledgement
[n][ ][Set ID][ ][OK/NG][Data][x]
24. Fail Over Select (Command: m i)
To select Fail Over mode.
Transmission
[m][i][ ][Set ID][ ][Data][Cr]
Data
00: Off
01: Auto
02: Manual
Acknowledgement
[i][ ][Set ID][ ][OK/NG][Data][x]
27. Tile Mode Check (Command: d z)
To check Tile Mode status.
Transmission
[d][z][ ][Set ID][ ][Data][Cr]
Data
FF: Check Tile Mode status
Acknowledgement
[z][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
Data1
00: Tile Mode Off
01: Tile Mode On
Data2
00 to 0F: Tile Col Value
Data3
00 to 0F: Tile Row Value
25. Fail Over Input Select (Command: m j)
To select fail over mode.
* Only available in Fail Over manual mode.
Transmission
[m][j][ ][Set ID][ ][Data1][ ][Data2][ ][Data3]
[ ][Data4][Cr]
Data(Priority 1~4)
60: RGB
70: DVI-D
90: HDMI
C0: Display Port
* Use 0x70 as data for DVI-D input, 0x90 as data
for HDMI input, 0xC0 as data for DisplayPort input,
regardless their input labels.
Acknowledgement
[j][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]