English - 9
4.2.1.2 Installation steps
1. Please adjust DIP switch at first prior to installation.
<Remark> Please refer to Chapter 7 DIP Switch Setting for the
relevant descriptions on DIP switch.
2. Place the camera on a flat desk directly to ensure the normal
vertical and horizontal operation of the machine.
4.2.2 I would like to install VC-G50 on the ceiling
4.2.2.1 Prepare for the parts and equipment required during the
installation
1. Accessories of VC-G50 in the box (metal plates A, B and M3
screw x 7)
2. Screw for locking on ceiling mounted hanger x 4
3. Drilling machine, screw driver, ladder
4.2.2.2 Dimension
Length x Width x Height : 174x186x182.7mm
Weight : 2.0Kg