Lynx R FR 5010 Computer Accessories User Manual


 
Reference Manual R FR 5010 Version1.4
Page 19
Extend Connection
Bus Extension. This connection is used to interface
racks together when using the optional LYNX
control system. This is a simple (and inexpensive)
way to extend the reach of the host RCT 5020
controller into several more racks fitted with RCT
5010 bus expanders. It uses a proprietary LYNX
control interface and this connection is physically
daisy chained between all connected racks.
Connection details can be seen in the table below.
The connection is a 9 pin SubD female connector.
Function and connection information is described
below.
Connector wiring detail when used for the Bus
Extension
Note the “prop” term refers to proprietary for the
LYNX interface.
Figure 7. Extend Connector
Note. When using this interface all connected racks
must be mounted close together, (preferably with
no space in-between racks), as the distance of this
interface is restricted. Please refer to the R CT 5010
Rack Bus Expander reference manual for more
details on this interface and the cables required.
Pin
Number
Connection
Pin
Number
Connection
1 Prop CLK A 6 Prop CLK B
2 Prop TX A 7 Prop TX B
3 Prop RX B 8 Prop RX A
4 GND 9 Prop SEL 2
5 Prop SEL 1