5101 rack frame may (due to the small airflow gap)
restrict the flow of air to this piece of equipment.
Also do not place equipment or objects on top of
the R FR 5010 rack frame that could restrict airflow
from the top of the rack. This may cause
malfunction and damage due to excessive heat
buildup.
Mechanical Installation
The R FR 5010 / R FR 5011 is secured into a standard
19-inch rack using 4 standard rack screws. Remove
front cover panel for installation, which allows
access to the rack ears (figure 3 shows location).
Rear support of the rack using rack rails is
recommended but not necessary.
Front Panel Removal R FR 5010
The front panel is removed by simply rotating the
thumbscrews one turn counterclockwise and
pulling the panel outwards.
Front Panel Removal R FR 5011
The front panel is removed by simply rotating the
thumbscrews one turn counterclockwise and
pulling the panel outwards.
If you put back the Fan Front Cover of the R FR 5011
please make sure that the 9 Pin Sub D connector
is connected correctly (see pictures below)