Maxon Telecom MM-6864 Modem User Manual


 
MM6854/64 Dual Band GSM Data Modem
ME 820047 Issue 1.0
Page 30 03/00
5.1.55 AT+FTH – Transmit HDLC data with carrier
Transmit data with HDLC Framing. +FTH=n causes the modem to receive data using HDLC protocol
and the modulation defined below. An ERROR response code results if this command is issued while
the modem is on-hook.
Enter
AT+FTH=<mod>
Where <mod>
3
AT+FTH=?
Response
V.21 300bps
Displays supported values
Notes:
None
Result codes:
OK
ERROR
5.1.56 AT+FTM – Transmit data with carrier
Transmit data. +FTM=n causes the modem to transmit data using the modulation defined below. An
ERROR response code results if this command is issued while the modem is on-hook.
Enter
AT+FTM=<mod>
Where <mod>
24
48
72
96
AT+FTM=?
Response
V.27 ter 2400bps
V.27 ter 4800bps
V.29 7200bps
V.29 9600bps
Displays supported values
Notes:
None
Result codes:
OK
ERROR
5.1.57 AT+GMI – Request manufacturer ID
This command provides the name of the manufacturer, i.e. Maxon.
Enter Response
Notes:
None
Result codes:
OK
ERROR
5.1.58 AT+GMM – Request model ID
This command provides the model name, i.e. MM-6854.