Metrologic Instruments Laser Scanner Scanner User Manual


 
5
INSTALLATION FOR OCIA INTERFACE
1. Follow the “Getting Started” steps on
page 3.
2. Turn off the host system.
3. Connect the MVC cable to the 10-pin
OCIA interface jack. It is the
2
nd
round opening from the left side of the
MS7220 (see figure 1).
4. Connect the other end of the MVC cable
to the host.
Before continuing verify that the MVC
cable is connected to the appropriate
interface jack on the scanner. An
incorrect cable connection can cause
communication problems or potential
damage to the scanner.
Plugging the scanner into the serial port
of the PC does not guarantee that
scanned information will appear at the
PC. A software driver and correct
configuration settings are also required
for proper communication.
5. Slide the cable cover into place on the
back of the scanner then secure it with the
three M3 screws provided.
6. Turn on the host system.
7. Scan the Load OCIA Defaults bar code to
configure the MS7220 for OCIA
communication.
For additional communication options for OCIA interfaces refer to the
MetroSelect Programming Guide (
MLPN 00-02407).
Caution:
To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements
for SELV (Safety Extra Low Voltage) according to EN 60950.
To maintain compliance with standard CSA C22.2 No. 60950-00//UL 60950 and norm EN 60950, the power source
should meet applicable performance requirements for a limited power source.
³999993
Load OCIA Defaults
Figure 1: OCIA, Interface