Metrologic Instruments MS1633 Barcode Reader User Manual


 
27
SCANNER OPERATION
Depth of Field by Minimum Bar Code Element Width
MINIMUM BAR CODE ELEMENT WIDTH
1D / PDF Data Matrix
A B C D E
F G
mm
.132 .19 .254 .33 .533
.254 .381
mils
5.2 7.5 10.4 13 21
10 15
Figure 31. Depth of Field by Minimum Bar Code Element Width
Decoding and functional capability of the unit is restricted through the use
of license numbers provided by Metrologic. Units will not support key
features such as, but not limited to, the ability to decode PDF, 2D or OCR
fonts without the proper licenses. Desired licenses can be specified at
the time of sale or call a Metrologic representative for more information.
Standard models ship with the ability to read all 1D, PDF and 2D bar
codes. OCR fonts are disabled by default and must be specifically
requested at an additional cost.
Specifications are subject to change without notice.