Metrologic Instruments MS7320 Barcode Reader User Manual


 
4
INSTALLATION FOR OCIA INTERFACE
1. Turn off the host system.
2. Connect the MVC cable to
the 10-pin OCIA interface jack. It is
the 2
nd
round opening from the left
side of the MS7320 (see figure 1).
3. Connect the other end of the MVC
cable to the host.
Before continuing verify that the MVC
cable is connected to the appropriate
interface jack on the scanner. An
incorrect cable connection can cause
communication problems or potential
damage to the scanner.
Plugging the scanner into the
serial port of the PC does not
guarantee that scanned
information will appear at the
PC. A software driver and
correct configuration settings are
also required for proper
communication.
4. Turn on the host system.
5. Scan the Load OCIA Defaults bar
code to configure the MS7320 for
OCIA communication.
6. Snap on the cable cover.
For additional communication options for OCIA interfaces refer to the
MetroSelect Configuration Guide (
MLPN 00-02407).
See SELV Power Source caution statement located on page 16 of this manual.
³999993
Load OCIA Defaults
Figure 1: OCIA, Interface