MGE UPS Systems EX30 Power Supply User Manual


 
Pulsar EX : 51032306XT/BB MGE UPS SYSTEMS
xii
options
c warranty extension up to 4 years
Pulsar 4: in certain countries, the standard
2-year guarantee can be extended to 4
years (batteries included) to ensure total
peace of mind;
c "Fault-tolerant" module: in the event of
an overload or a fault on the UPS, the
bypass switches the load to AC power
without any interruption. If your Pulsar EX is
fitted with this module, check with your usual
installation electrician that the electrical
installation is compatible;
c "Hot-swap" pack: made up of the
"Fault-tolerant" module and a withdrawable
manual bypass. The Pulsar EX can be
turned off, without interrupting the power
supply to the load, and serviced in complete
safety. This plug-in module enables the
faulty UPS to be replaced without
interrupting the power supply to the load
(hot-swap feature). The UPS is available
with optional USE, DIN, BS or IEC230
outlets. As a standard feature, it is fitted with
an IEC320/C20 socket for connection to the
input source and terminal blocks for
upstream and downstream connections,
depending on the selected configuration;
c "Install" pack: offers the same functions
as the "Hot-swap" pack with connection by
terminal block only;
c additional outlet block: to increase the
number of output sockets to the Pulsar EX
(consult our catalogue);
c rack installation kit: this kit is used to
install Pulsar EX in a 19-inch rack;
c Pulsar EXB battery extension modules:
Pulsar EXB modules helps boost the battery
time of the Pulsar EX to meet your service
continuity requirements;
c isolating transformer: designed to
maintain complete galvanic isolation
(input/ouput) of Pulsar EX fitted with a
bypass ("Fault-tolerant", "Hot-swap" or
"Install" version);
c UM Sensor environment monitoring
unit: compatible with our Solution-Pac™
and Management-Pac™ software offer, this
unit measures the temperature and relative
humidity in the room where it is installed.
Eight relay contacts are provided to transmit
signals, in the form of volt free contacts or
voltage levels to enable monitoring of fire
alarms, climate control faults, intrusion
alarms, etc.;
c UM-Switch™ module for extended
Powershare functionality: UM-Switch is
available as an option with Pulsar EX,
bringing you Powershare power sharing
features on a PC or network management
station (with Solution-Pac™). UM-Switch
outputs can be remotely controlled for:
v remote reset of faulty devices (for
example, a module in a hub stack),
v allocation of specific battery backup times
to each output allowing early shutdown of
non-critical devices, increasing the time
available to priority devices, such as servers
or interconnection devices,
v programming of startup sequences so that
systems can be started in a specific order or
to prevent overloading caused by starting
several devices simultaneously,
v monitoring the power supply to each
protected device;
c Monitor Light™: this mini-terminal
enables users to monitor Pulsar EX
operating modes - load on battery, load on
automatic bypass, etc. - at distances of up to
a hundred metres and receive any alarm
messages (low-battery shutdown warnings,
mains outage, operation on bypass, etc.).
c communication cables: these cables are
used for the file-closing utilities offered by a
number of network operating systems. They
are available for Novell NetWare, Microsoft
Lan Manager and Windows NT, IBM Lan
Server, IBM AS400, Artisoft LANtastic,
Banyan Vines, and many others;
c Management-Pac™: if your company
uses administration platforms such as
HP Open View, IBM Netview 6000, Sun
Solstice, Novell ManageWise, you can use
the Management-Pac™ CD-ROM (option) to
display and manage your Pulsar EX UPS
from your supervision screen.
Contact your dealer for further
information on these options.
Note: brand and product names are registered
trademarks of their respective holders.