Mitsubishi Electronics LVP-X300U Projector User Manual


 
AP 2
Control this projector by using a personal computer
1) Interface
This projector can be controlled by connecting a personal computer with RS-232C terminal.
Functions can be controlled by a personal computer:
Turn the ON or OFF
Changing input signals
Button input by remote control or control panel
Reading warning data
Menu setting
Connection
Projector + IBM PC or IBM PC compatibles
RS-232C cable
to RS-232C
terminal
to Com1
Comport
D-SUB 9P D-SUB 9P
Note: If your PC (IBM or IBM compatible) is equipped only with a 25-pin serial port connector, a 25-pin
serial port adapter is required. Contact your dealer for details.
to RS-232C
terminal
RS-232C adaptor
for Macintosh (option)
to modem port
or printer port
D-SUB 9P D-SUB 9PD-SUB 9PMini DIN 8P
PROTOCOL RS-232C
BAUD RATE 9600 [bps]
DATA LENGTH 8 [bits]
PARITY BIT NONE
STOP BIT 1 [bits]
FLOW CONTROL NONE
This projector uses RXD, TXD and GND lines for RS-232C control.
For RS-232C cable,the reverse type cable should be used.
2) Control command diagram
The command is structured by the address code, function code, data code and end code. The length of the
command is different by each function.
Address code Function code Data code End code
HEX 30h 30h Function Data 0Dh
ASCII '0' '0' Function Data
[Address code] 30h 30h (In ASCII code, '0' '0') fixed.
[Function code] A code of each fixed control move.
[Data code] A code of each fixed control data (number) and not always indicated.
[End code] 0Dh (In ASCII code, ' ') fixed.