FEATURES
4. i-see Sensor (OPTIONAL CORNER PANEL)
The i see sensor is a radiation temperature sensor originated from Mitsubishi’s new technology. In order to create a really
comfortable space in shops and offices, it is essential to control the temperature near the floor where occupants/visitors
gather. The i see sensor measures the infrared rays generated from the surrounding wall and floor surface at an angle of
360° and the infrared ray energy is computed to convert it into the value of temperature. In addition, the floor temperature
at distant spots (radiation temperature) is also measured to supply the optimum airflow to realize comfort which was never
experienced in the past.
Models
Cooling capacity / Heating capacity
PLFY-P12NBMU-E 12,000 / 13,500 Btu/h
PLFY-P15NBMU-E 15,000 / 17,000 Btu/h
PLFY-P18NBMU-E 18,000 / 20,000 Btu/h
PLFY-P24NBMU-E 24,000 / 27,000 Btu/h
PLFY-P30NBMU-E 30,000 / 34,000 Btu/h
PLFY-P36NBMU-E 36,000 / 40,000 Btu/h
Indoor Unit
Operation image of "Wave Airflow"
HighLow
Automatic air
speed adjustment
Medium 2
Medium 1
1. WIDE AIRFLOW
The new wide shape vane capable of wide angle air supply provides comfort even at the corners of a room regardless
of cooling and heating operation. A reduction in the air speed by 20% compared to the conventional product eliminates
uncomfortable draft sensation for friendly air conditioning.
2. WAVE AIRFLOW SYSTEM (HEATING MODE)
The wave airflow system has 4 vanes where each vane runs independently. Repeating of horizontal and down blows with a
time lag allows the conditioned warm air to be distributed even to room corners thus preventing uneven room temperature
distribution.
3. AUTOMATIC AIR SPEED ADJUSTMENT MODE
The automatic air speed adjustment mode is provided in addition to the 4 air speed stages of "High/Medium 1/Medium 2/
Low." Air speed can be changed freely in accordance with a difference between the set temperature and the room tempera-
ture. The automatic air speed adjustment mode presents quick cooling of a room with the high mode, such as at the start-
ing up of cooling operation, for example. After the room temperature is stabilized, the low mode will be applied by automatic
switching to keep your comfort.
1
TECHNICAL CHANGES
PLFY-P12NBMU-E PLFY-P12NBMU-ER1
PLFY-P15NBMU-E PLFY-P15NBMU-ER1
PLFY-P18NBMU-E PLFY-P18NBMU-ER1
PKFY-P24NBMU-E PLFY-P24NBMU-ER1
PKFY-P30NBMU-E PLFY-P30NBMU-ER1
PKFY-P36NBMU-E PLFY-P36NBMU-ER1
INDOOR CONTROLLER BOARD (I.B.) has been changed.