DX-VS1UE User
DX-VS1UE UserDX-VS1UE User
DX-VS1UE User’
’’
’s Manual
s Manuals Manual
s Manual
26
PTZ Command for Manual Script
1. Escape Characters
# Special command
@ Hexadecimal character
% Decimal character
^ Character
, Break character
; End of current packet
& Special operation
2. Special command (Followed by #)
A Address assigned by pan/tilt/zoom configuration
X Acceleration rate selected by user
S
x
Checksum calculation method
x
= 0 Sum of entire frame, size = 1byte
x = 1 Sum of entire frame, size = 2byte
x = 2 Sum of entire frame except first byte(sync), size = 1byte
x = 3 Sum of entire frame except first byte(STX) and last byte(ETX), size = 1byte
x = 4 Sum and one's complement of entire frame except first byte(STX) and last byte(ETX),
size = 1byte
x = 5 XOR sum of entire frame, size = 1byte
x = 6 XOR sum of entire frame, size = 2byte
x
= 7 XOR sum of entire frame except first byte(sync), size = 1byte
x
= 8 XOR sum of entire frame except first byte(STX) and last byte(ETX), size = 1byte
x
= 9 XOR sum and one's complement of entire frame except first byte(STX) and last byte(ETX),
size = 1byte
3. Special Operation (Followed by &)
Sx Delay about ( ([acceleration rate] + 1) * (100 * x) ) ms
x 0 ~ 4
4. Exceptions
Normal character following Escape Sequence, must use break character for identifying the end of sequence
* Some protocols are not to be made command script with above method. It is because they use anothe
r
method of checksum calculation.