Momentum Sales & Marketing MO8ME Network Card User Manual


 
14
Momentum mo8me Manual
The mo8me does not require a start channel. The unit is shipped with routing channels pre-set to
Network input channels 1-32. This function can be used to change the factory default if required,
to another set of 32 sequential channels.
The start channel, in this case, will be the rst of the selected sixteen inputs. While in resting or
time-out mode, the mo8me will display “- - -” . Channels are set in grouping of thirty-two i.e.
1-32, 33-64, 65-96 etc.
Start Channel Route
Connection and Setup
Chapter 2
An IP address will need to be set only if the Momentum
network will be controlled with a PC or external controller.
The IP address defaults to 192.168.1.1. When in the idle
menu state, pressing the F1 key will ash the current ad-
dress. The number shown is the LSB of the IP address
(192.168.1.[LSB]). If the network is to be controlled with
a PC, each mi8 unit will need a unique IP address. All IPs
need to be set manually on the individual unit.
It is best practice to keep the input unit’s IP address sequential with its channel. In other words,
Chn 001-008 would be Adr 001 and Chn 009-016 would be Adr 002 and so on.
PLEASE NOTE: The mo8me can ONLY be set at a sample rate of 48k. All other network
devices must also be 48k. A setting for sample rate 96k has been added for future use, but it is
not available at this time. You will be unable to execute and save this sample rate change.
IP Address
Sample Rate
THE FOLLOWING FRONT PANEL SETTINGS MUST BE CONFIGURED PRIOR TO USING MOMENTUM.
The IP setting is required only if the unit is to be controlled with a PC or external controller.
A detailed description of control functions can be found in chapter 3, pages 16-17.
Setting Device Before Use